Catheter Introducer – Novel peel-away sheath introducer set (PASIS) with integrated sealing system
The introduction of a device (e.g. a catheter) into a vessel of the human or animal body to accomplish a medical procedure is accompanied with some fundamental problems. The device must be inserted through a puncture site in the vessel wall into the lumen of the vessel what causes bleeding and maybe wall trauma. To minimize this risks sheath introducers and hemostatic agents are used. Despite these approaches the problems havn´t been fully solved yet and a reliable, safe and easy to use device and method are still needed.
The invention presented here overcomes the limitations of the prior art and provides a catheter introducing system by means of which bleeding can be prevented and wall trauma can be minimized. The innovative device combines a peel-away sheath introducer set with a splittable hemostasis valve and an integrated sealing system. The new peel-away introducer set is composed of three coaxial arranged peelable cannulae: an access cannula, a pusher and a sealing cannula. The pusher and the sealing cannula are mounted on the access cannula in a movable manner. A collagen cuff is integrated into the sealing cannula in such a way that the collagen can be positioned by the pusher at the puncture site where the collagen acts as a surgical sealant. This system allows an effective sealing of the puncture wound after removal of the access cannula. In addition, the introducer set contains a splittable hemostasis valve to prevent reflux of liquid (e.g. blood) from the punctured vessel during the implantation procedure. The present invention could be used for procedures where a device has to be introduced into a vessel of the human or animal body. As an example the sheath introducer can be applied to establish a fully implantable and telemetrically controlled blood pressure system comprising an implant with a sensor and a telemetry unit which is connected via micro-cable with the sensor.
Weitere Informationen: PDF
PROvendis GmbH
Tel.: +49 (0)208/94105 10
Ansprechpartner
Dipl.-Ing. Alfred Schillert
Media Contact
Alle Nachrichten aus der Kategorie: Technologieangebote
Neueste Beiträge
Magnetischer Speicher mit energieeffizientem MRAM freigeschaltet
Forscher der Universität Osaka stellen innovative Technologie zur Senkung des Energieverbrauchs moderner Speichervorrichtungen vor. Fortschritt in der Speichertechnologie: Überwindung der Grenzen traditioneller RAM Osaka, Japan – In den letzten Jahren…
Next-Level System-Sicherheit: Intelligenterer Zugriffsschutz für Organisationen
Fortschrittliches Framework zur Verbesserung der System-Sicherheit Forschende der University of Electro-Communications haben ein bahnbrechendes Framework zur Verbesserung der System-Sicherheit durch die Analyse von Geschäftsprozessprotokollen entwickelt. Dieses Framework konzentriert sich darauf,…
Wie mikrobielles Leben die Kalkbildung im tiefen Ozean beeinflusst
Mikroorganismen sind überall und beeinflussen die Umwelt der Erde seit über 3,5 Milliarden Jahren. Forschende aus Deutschland, Österreich und Taiwan haben nun erstmals die Rolle entschlüsselt, die Mikroorganismen bei der…